I ran out of propane and now the water heater pilot light will not stay lit
.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty{ margin-bottom:0;
}
up vote
8
down vote
favorite
I had run out of propane. Now that I have propane, I can’t get the pilot light to stay lit on my water heater, nor will it stay lit even long enough to light the burner.
Click for larger view:
water-heater propane pilot-light
add a comment |
up vote
8
down vote
favorite
I had run out of propane. Now that I have propane, I can’t get the pilot light to stay lit on my water heater, nor will it stay lit even long enough to light the burner.
Click for larger view:
water-heater propane pilot-light
7
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32
add a comment |
up vote
8
down vote
favorite
up vote
8
down vote
favorite
I had run out of propane. Now that I have propane, I can’t get the pilot light to stay lit on my water heater, nor will it stay lit even long enough to light the burner.
Click for larger view:
water-heater propane pilot-light
I had run out of propane. Now that I have propane, I can’t get the pilot light to stay lit on my water heater, nor will it stay lit even long enough to light the burner.
Click for larger view:
water-heater propane pilot-light
water-heater propane pilot-light
edited Nov 28 at 13:23
Machavity
6,30011634
6,30011634
asked Nov 27 at 19:21
Brandon Jolene Lively
4112
4112
7
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32
add a comment |
7
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32
7
7
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32
add a comment |
5 Answers
5
active
oldest
votes
up vote
31
down vote
I have had similar problems in the past when running out, what I found is I had to hold the pilot for several minutes to get the lines full of propane again. I found it easiest to light the stove top or try until it would burn then I went to the furnace and water heater it still took a few minutes as the pilot is a very small draw but once the lines had properly purged I had no problems after that, it was like some air was in the lines would light burn funny and go out, once I got a solid flame the problem was solved.
add a comment |
up vote
13
down vote
My understanding of pilot lights is that they heat a thermocouple, which is a mass of metal that detects heat. The electronics behind that thermocouple will shut off the gas to the pilot if the thermocouple gets cold so that if something blows out the pilot you don't have a gas leak in your home. The side effect is that you have to heat up that mass of metal manually when you light the pilot. This is usually done by manually holding the valve open for a while when the pilot is first lit. (My gas fireplace says to do this for at least a minute, but it's usually good after 15 seconds.)
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
add a comment |
up vote
0
down vote
Easy way to purge the line is to losen the black iron drip leg.
Shut gas off to heater lossen drip leg ,turn gas on. Gas will flow out pushing air while this is happening tighten drip leg. Earlier post is correct small draw at pilot by opening up tje drip leg you have more flow. Be sure to reseal drip leg with thread seal (pipe dope)
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
add a comment |
up vote
0
down vote
Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.
add a comment |
up vote
0
down vote
First, any time I can, I use a propane torch to heat the thermocouple and light the pilot. This allows time for all the air to get out of the line and gets the thermocouple nice and hot again.
About 90% of the time, the propane torch works well the first time.
Second, if the waterheater is off longer than a few hours, you may have to relight it several times. Have no explanation for this, but it's an observation after 30 years of watching renters do crazy stuff! If the intervals between lightings is getting longer, I'd keep checking three times a day and relighting.
Third, I've had to replace two burner units due to the switch mentioned above. It's fairly straight forward to replace the units, just take care to properly fit, thread, and seal the joints. (Know what to do for each type of joint.) Then test all the joints, including those that you didn't believe that you touched with soapy water to see gas leaks.
In both cases, Whirlpool was very nice about sending a new burner unit under warranty, even after they'd sent new thermocouples that didn't help!
add a comment |
5 Answers
5
active
oldest
votes
5 Answers
5
active
oldest
votes
active
oldest
votes
active
oldest
votes
up vote
31
down vote
I have had similar problems in the past when running out, what I found is I had to hold the pilot for several minutes to get the lines full of propane again. I found it easiest to light the stove top or try until it would burn then I went to the furnace and water heater it still took a few minutes as the pilot is a very small draw but once the lines had properly purged I had no problems after that, it was like some air was in the lines would light burn funny and go out, once I got a solid flame the problem was solved.
add a comment |
up vote
31
down vote
I have had similar problems in the past when running out, what I found is I had to hold the pilot for several minutes to get the lines full of propane again. I found it easiest to light the stove top or try until it would burn then I went to the furnace and water heater it still took a few minutes as the pilot is a very small draw but once the lines had properly purged I had no problems after that, it was like some air was in the lines would light burn funny and go out, once I got a solid flame the problem was solved.
add a comment |
up vote
31
down vote
up vote
31
down vote
I have had similar problems in the past when running out, what I found is I had to hold the pilot for several minutes to get the lines full of propane again. I found it easiest to light the stove top or try until it would burn then I went to the furnace and water heater it still took a few minutes as the pilot is a very small draw but once the lines had properly purged I had no problems after that, it was like some air was in the lines would light burn funny and go out, once I got a solid flame the problem was solved.
I have had similar problems in the past when running out, what I found is I had to hold the pilot for several minutes to get the lines full of propane again. I found it easiest to light the stove top or try until it would burn then I went to the furnace and water heater it still took a few minutes as the pilot is a very small draw but once the lines had properly purged I had no problems after that, it was like some air was in the lines would light burn funny and go out, once I got a solid flame the problem was solved.
answered Nov 27 at 19:27
Ed Beal
29.6k12043
29.6k12043
add a comment |
add a comment |
up vote
13
down vote
My understanding of pilot lights is that they heat a thermocouple, which is a mass of metal that detects heat. The electronics behind that thermocouple will shut off the gas to the pilot if the thermocouple gets cold so that if something blows out the pilot you don't have a gas leak in your home. The side effect is that you have to heat up that mass of metal manually when you light the pilot. This is usually done by manually holding the valve open for a while when the pilot is first lit. (My gas fireplace says to do this for at least a minute, but it's usually good after 15 seconds.)
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
add a comment |
up vote
13
down vote
My understanding of pilot lights is that they heat a thermocouple, which is a mass of metal that detects heat. The electronics behind that thermocouple will shut off the gas to the pilot if the thermocouple gets cold so that if something blows out the pilot you don't have a gas leak in your home. The side effect is that you have to heat up that mass of metal manually when you light the pilot. This is usually done by manually holding the valve open for a while when the pilot is first lit. (My gas fireplace says to do this for at least a minute, but it's usually good after 15 seconds.)
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
add a comment |
up vote
13
down vote
up vote
13
down vote
My understanding of pilot lights is that they heat a thermocouple, which is a mass of metal that detects heat. The electronics behind that thermocouple will shut off the gas to the pilot if the thermocouple gets cold so that if something blows out the pilot you don't have a gas leak in your home. The side effect is that you have to heat up that mass of metal manually when you light the pilot. This is usually done by manually holding the valve open for a while when the pilot is first lit. (My gas fireplace says to do this for at least a minute, but it's usually good after 15 seconds.)
My understanding of pilot lights is that they heat a thermocouple, which is a mass of metal that detects heat. The electronics behind that thermocouple will shut off the gas to the pilot if the thermocouple gets cold so that if something blows out the pilot you don't have a gas leak in your home. The side effect is that you have to heat up that mass of metal manually when you light the pilot. This is usually done by manually holding the valve open for a while when the pilot is first lit. (My gas fireplace says to do this for at least a minute, but it's usually good after 15 seconds.)
edited Nov 28 at 16:11
Ryan Keshock
31
31
answered Nov 27 at 23:02
Sam
418214
418214
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
add a comment |
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
Disagree. That's why you have to hold the control down while lighting the pilot. That bypasses the cold = stop the gas safety.
– Loren Pechtel
Nov 28 at 1:44
20
20
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
@LorenPechtel, your grammar is difficult to decipher, but I think you are literally saying what I am saying.
– Sam
Nov 28 at 1:49
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
my gas fireplace goes out after a few minutes of being on and the pilot goes out too, hard to imagine it getting cold but now i have a lead.
– Jordan.J.D
Nov 28 at 17:11
add a comment |
up vote
0
down vote
Easy way to purge the line is to losen the black iron drip leg.
Shut gas off to heater lossen drip leg ,turn gas on. Gas will flow out pushing air while this is happening tighten drip leg. Earlier post is correct small draw at pilot by opening up tje drip leg you have more flow. Be sure to reseal drip leg with thread seal (pipe dope)
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
add a comment |
up vote
0
down vote
Easy way to purge the line is to losen the black iron drip leg.
Shut gas off to heater lossen drip leg ,turn gas on. Gas will flow out pushing air while this is happening tighten drip leg. Earlier post is correct small draw at pilot by opening up tje drip leg you have more flow. Be sure to reseal drip leg with thread seal (pipe dope)
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
add a comment |
up vote
0
down vote
up vote
0
down vote
Easy way to purge the line is to losen the black iron drip leg.
Shut gas off to heater lossen drip leg ,turn gas on. Gas will flow out pushing air while this is happening tighten drip leg. Earlier post is correct small draw at pilot by opening up tje drip leg you have more flow. Be sure to reseal drip leg with thread seal (pipe dope)
Easy way to purge the line is to losen the black iron drip leg.
Shut gas off to heater lossen drip leg ,turn gas on. Gas will flow out pushing air while this is happening tighten drip leg. Earlier post is correct small draw at pilot by opening up tje drip leg you have more flow. Be sure to reseal drip leg with thread seal (pipe dope)
answered Nov 28 at 3:51
Mike
91
91
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
add a comment |
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
5
5
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
While I don't disagree with you, this feels like it need to come with big warnings about using non-sparking tools, proper ventilation, etc. Having a cloud (even a small one) of propane hanging out in the basement sounds like a Bad Thing™
– FreeMan
Nov 28 at 15:34
1
1
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
Good lord. I don't think the average joe should do this.
– enorl76
Nov 29 at 1:40
add a comment |
up vote
0
down vote
Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.
add a comment |
up vote
0
down vote
Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.
add a comment |
up vote
0
down vote
up vote
0
down vote
Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.
Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.
answered Nov 28 at 15:08
Dan
1
1
add a comment |
add a comment |
up vote
0
down vote
First, any time I can, I use a propane torch to heat the thermocouple and light the pilot. This allows time for all the air to get out of the line and gets the thermocouple nice and hot again.
About 90% of the time, the propane torch works well the first time.
Second, if the waterheater is off longer than a few hours, you may have to relight it several times. Have no explanation for this, but it's an observation after 30 years of watching renters do crazy stuff! If the intervals between lightings is getting longer, I'd keep checking three times a day and relighting.
Third, I've had to replace two burner units due to the switch mentioned above. It's fairly straight forward to replace the units, just take care to properly fit, thread, and seal the joints. (Know what to do for each type of joint.) Then test all the joints, including those that you didn't believe that you touched with soapy water to see gas leaks.
In both cases, Whirlpool was very nice about sending a new burner unit under warranty, even after they'd sent new thermocouples that didn't help!
add a comment |
up vote
0
down vote
First, any time I can, I use a propane torch to heat the thermocouple and light the pilot. This allows time for all the air to get out of the line and gets the thermocouple nice and hot again.
About 90% of the time, the propane torch works well the first time.
Second, if the waterheater is off longer than a few hours, you may have to relight it several times. Have no explanation for this, but it's an observation after 30 years of watching renters do crazy stuff! If the intervals between lightings is getting longer, I'd keep checking three times a day and relighting.
Third, I've had to replace two burner units due to the switch mentioned above. It's fairly straight forward to replace the units, just take care to properly fit, thread, and seal the joints. (Know what to do for each type of joint.) Then test all the joints, including those that you didn't believe that you touched with soapy water to see gas leaks.
In both cases, Whirlpool was very nice about sending a new burner unit under warranty, even after they'd sent new thermocouples that didn't help!
add a comment |
up vote
0
down vote
up vote
0
down vote
First, any time I can, I use a propane torch to heat the thermocouple and light the pilot. This allows time for all the air to get out of the line and gets the thermocouple nice and hot again.
About 90% of the time, the propane torch works well the first time.
Second, if the waterheater is off longer than a few hours, you may have to relight it several times. Have no explanation for this, but it's an observation after 30 years of watching renters do crazy stuff! If the intervals between lightings is getting longer, I'd keep checking three times a day and relighting.
Third, I've had to replace two burner units due to the switch mentioned above. It's fairly straight forward to replace the units, just take care to properly fit, thread, and seal the joints. (Know what to do for each type of joint.) Then test all the joints, including those that you didn't believe that you touched with soapy water to see gas leaks.
In both cases, Whirlpool was very nice about sending a new burner unit under warranty, even after they'd sent new thermocouples that didn't help!
First, any time I can, I use a propane torch to heat the thermocouple and light the pilot. This allows time for all the air to get out of the line and gets the thermocouple nice and hot again.
About 90% of the time, the propane torch works well the first time.
Second, if the waterheater is off longer than a few hours, you may have to relight it several times. Have no explanation for this, but it's an observation after 30 years of watching renters do crazy stuff! If the intervals between lightings is getting longer, I'd keep checking three times a day and relighting.
Third, I've had to replace two burner units due to the switch mentioned above. It's fairly straight forward to replace the units, just take care to properly fit, thread, and seal the joints. (Know what to do for each type of joint.) Then test all the joints, including those that you didn't believe that you touched with soapy water to see gas leaks.
In both cases, Whirlpool was very nice about sending a new burner unit under warranty, even after they'd sent new thermocouples that didn't help!
answered Nov 29 at 3:04
Larry Paden
1
1
add a comment |
add a comment |
Thanks for contributing an answer to Home Improvement Stack Exchange!
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
To learn more, see our tips on writing great answers.
Some of your past answers have not been well-received, and you're in danger of being blocked from answering.
Please pay close attention to the following guidance:
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
To learn more, see our tips on writing great answers.
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f151425%2fi-ran-out-of-propane-and-now-the-water-heater-pilot-light-will-not-stay-lit%23new-answer', 'question_page');
}
);
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
7
What start procedure are you using? What's the model number of the machine?
– Harper
Nov 27 at 20:32